[Jan 08, 2022] Pass 5V0-21.21 Review Guide, Reliable 5V0-21.21 Test Engine [Q16-Q38]

Share

[Jan 08, 2022] Pass 5V0-21.21 Review Guide, Reliable 5V0-21.21 Test Engine

5V0-21.21 Test Engine Practice Test Questions, Exam Dumps


VMware 5V0-21.21 Exam Syllabus Topics:

TopicDetails
Topic 1
  • identify the appropriate action to troubleshoot performance issues in a vSAN deployment
  • Identify vSAN data placement changes (stretches clusters, fault aomains)
Topic 2
  • Given a scenario, identify the implications of integrating VMware solutions with vSAN
  • Given a scenario, identify the use cases for an HCI Mesh infrastructure
Topic 3
  • Given a scenario, identify how to apply the appropriate maintenance mode option
  • Given a scenario, identify the apDropriate action to recover from a vSAN or infrastructure failure
Topic 4
  • VMware Products and Solutions
  • Given a scenario, identify the VMware products and solutions that will interact with a vSAN solution

 

NEW QUESTION 16
A company hosts a vSAN 7 stretched cluster for all development workloads. The original sizing of a maximum of 250 concurrent workloads in the vSAN cluster is no longer sufficient and needs to increase to at least 500 concurrent workloads within the next six months.
To meet this demand, the original 8-node (4-4-1) cluster has recently been expanded to 16 nodes (8-8-1).
Which three additional steps should the administrator take to support the current growth plans while minimizing the amount of resources required at the witness site? (Choose three.)

  • A. Upgrade the vSAN stretched cluster to vSAN 7.0 U1.
  • B. Deploy a new large vSAN witness appliance at the witness site.
  • C. Add the new vSAN witness appliance to vCenter Server.
  • D. Configure the vSAN stretched cluster to use the new vSAN witness.
  • E. Configure the new vSAN witness as a shared witness appliance.
  • F. Deploy a new extra large vSAN witness appliance at the witness site.

Answer: B,D,E

 

NEW QUESTION 17
An architect is designing a vSAN cluster.
Which storage controller option will yield optimal performance?

  • A. Enable battery write-back caching
  • B. Hugh queue depth
  • C. RAID 0
  • D. Set caching to 50% read on the controller

Answer: C

 

NEW QUESTION 18
An administrator of "vsan-prod" cluster noticed the witness components of VMs are flagged as absent after a failed attempt to replace the vSAN Witness Host.
Which action should the administrator take to resolve this issue?

  • A. Running the vSAN Skyline Health check to ensure there are vSAN Object Health errors and executing the Repair Object Immediately option
  • B. Placing the vSAN Witness Host in Maintenance Mode and adding to the vSAN cluster
  • C. Upgrading the vSAN on-disk format
  • D. Using the RVC command: vsan.resync_dashboard ~/computers/vsan-prod

Answer: B

 

NEW QUESTION 19
An administrator wants to enable encryption on an existing vSAN cluster that already contains virtual machines.
Which additional step should the administrator take to ensure no data is lost during the encryption process?

  • A. Make vCenter Server trust the KMS, either by trusting the KMS or by uploading a KMS certificate.
  • B. Disable vSphere Distributed Resources Schedule (DRS) on the vSAN cluster.
  • C. Ensure that the vSAN Encryption is enabled by default on the existing cluster to encrypt old and new data.
  • D. Select 'Erase disks before use' check box when enabling encryption on a vSAN cluster.

Answer: D

 

NEW QUESTION 20
An administrator is planning to change a vSAN Storage Policy to apply a Failures To Tolerate (FTT) of 2, using RAID-6.
What is the minimum number of vSAN nodes required?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

 

NEW QUESTION 21
After a vSAN Witness Appliance network configuration, the vSAN administrator notices that vSAN traffic flows from vmk0 (Management Traffic) rather than vmk1 (vSAN Traffic).
Which step should be taken to resolve this issue?

  • A. Configure vmk1 with IP address on the different network than that of vmk0.
  • B. Tag the vmk1 for Witness traffic.
  • C. Configure vmk0 with IP address on the same range as that of vmk1.
  • D. Tag the vmk0 for vSAN traffic.

Answer: C

Explanation:
If both vmk0 and vmk1 are configured on the same range, a multihoming condition will occur and vSAN traffic will flow from vmk0, rather than vmk1.

 

NEW QUESTION 22
Which statement accurately describes the result when proper VM Storage Policy Affinity Rules on a stretched vSAN cluster are set?

  • A. When a site is disconnected, the VM will continue to have access to its VMDK.
  • B. Bandwidth is unnecessarily sent across the inter-site link.
  • C. When a site is disconnected, the VM will lose access to its VMDK.
  • D. Proper policies result in higher inter-site bandwidth utilization.

Answer: C

 

NEW QUESTION 23
Due to the success of the recently deployed developer-only private cloud solution, a company has a new requirement to at least double the usable capacity in their all-flash vSAN cluster.
The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.
The current vSAN cluster has the following configuration:
* 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM
* 1 Disk Group per vSAN node
- 1 x 400 GB
- 4 x 1.8 TB
* De-duplication and Compression is enabled.
* vSAN Capacity is currently:
- Total: 72 TB
- Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).
As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.
Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)

  • A. Install an additional 400 GB SSD and 4 x 1.8 TB SSDs per vSAN node.
  • B. Update the existing Disk Group, and claim the newly installed drives for each node.
  • C. Create a new Disk Group, and claim the newly installed cache and capacity SSD drives for each node.
  • D. Replace existing SSDs with an 800 GB SSD and 4 x 3.8 TB SSDs per vSAN node.
  • E. Install an additional 3 x 1.8 TB SSDs per vSAN node.

Answer: C,E

 

NEW QUESTION 24
An administrator has been tasked with enabling encryption for existing virtual machines on a vSAN cluster.
Which three prerequisites must be satisfied before completing the task? (Choose three.)

  • A. Establish a trusted connection with the KMS
  • B. Enable Data-In-Transit encryption first
  • C. Verify if a role with privilege "Cryptographic operations.Migrate" is assigned
  • D. Enable that the virtual machines are powered on
  • E. Verify if a role with privilege "Cryptographic operations.Encrypt new" is assigned
  • F. Create an encryption storage policy

Answer: A,D,E

 

NEW QUESTION 25
An administrator has an absent capacity disk.
Which action, if any, should the administrator take to resolve the problem?

  • A. Verify the host is not isolated.
  • B. Replace the faulty host.
  • C. Wait, and vSAN will rebuild it.
  • D. Replace the faulty disk.

Answer: C

 

NEW QUESTION 26
An architect collected the below technical requirements from the customer during a vSAN cluster design workshop:
* Maximize the vSAN datastore usable capacity.
* Deduplication and compression are required to help utilize available capacity efficiency.
* Ensure the highest level of resiliency wherever possible.
Which disk group configuration should the architect include in the design?

  • A. One disk group per host, with one cache tier flash disk and four capacity tier flash disks.
  • B. Two disk groups per host, each with one cache tier flash disk and four capacity tier flash disks.
  • C. Two disk groups per host, each with one cache tier flash disk and six capacity tier flash disks.
  • D. Two disk groups per host, each with one cache tier flash disk and six capacity tier magnetic disks.

Answer: D

 

NEW QUESTION 27
An administrator wants to check the performance metrics for the workloads and their virtual disks that are running on a vSAN cluster, but no statistical charts are displayed in the vSphere client.
Why is this behavior being seen?

  • A. vSAN network diagnostic mode is not enabled.
  • B. vSAN performance service is turned off.
  • C. vSAN proactive tests haven't been run yet.
  • D. vSAN performance verbose mode is not enabled.

Answer: B

Explanation:
Some tools allow for measuring latency peaks. This unfortunately isn't ideal, as it can unfairly represent statistical outliers, which may very well occur when there is little to no I/O activity. The best way to understand the actual behavior of VM and application latencies is to observe in time based performance graphs. Depending on the level of detail, you may need to measure at the individual VMDK level. Become familiar with these graphs to determine what is normal, and what is not for that given application. This is where you can use built-in functionality of vCenter and the vSAN performance service metrics to gather this information.

 

NEW QUESTION 28
An administrator is tasked with sharing storage from one vSAN cluster to another vSAN cluster. SPBM management must be preserved end-to-end, and the policy must be applied by the source vSAN cluster which is storing the dat a. Both vSAN clusters are managed by the same vCenter server.
What should the administrator configure?

  • A. iSCSI targets on vSAN
  • B. HCI Mesh on vSAN
  • C. vVOLs on vSAN
  • D. NFS volumes on vSAN

Answer: B

 

NEW QUESTION 29
for a customer who is planning to use vRealize Automation to provision 600 virtual machines into that cluster, with expected growth up to 1,000 VM. Each VM has a 40GB thick-provisioned disk.
Which flash disk size is required for the cache tier per ESXi node to meet all requirements?

  • A. 600GB
  • B. 700GB
  • C. 400GB
  • D. 800GB

Answer: D

 

NEW QUESTION 30
An administrator is tasked with migrating a VMware Horizon View environment that is currently running on an NFS Datastore to VMware vSAN.
Which Horizon configuration option will not be available when configuring vSAN in Horizon View?

  • A. Instant Clones
  • B. Storage Profiles
  • C. Linked Clones
  • D. Storage Tiers

Answer: D

 

NEW QUESTION 31
During a vSAN design workshop, an architect collected these customer requirements:
* Leverage vSAN storage policies with Erasure Coding.
* Enable Deduplication and Compression.
* Use the minimum number of hosts in the cluster.
* Maintain full storage policy compliance when two nodes are down.
Which vSAN cluster design meets the customer's requirements?

  • A. Five nodes Hybrid vSAN cluster
  • B. Six nodes All-Flash vSAN cluster
  • C. Six nodes Hybrid vSAN cluster
  • D. Five nodes All-Flash vSAN cluster

Answer: B

 

NEW QUESTION 32
An administrator wants to deploy Kubernetes on an end-to-end VMware stack, using VMware vSAN for storage.
Which VMware product should the administrator install as the Kubernetes platform choice?

  • A. VMware Tanzu Kubernetes Grid
  • B. VMware Tanzu Build service
  • C. VMware Tanzu Mission Control
  • D. VMware Tanzu Data services

Answer: A

 

NEW QUESTION 33
A company has deployed a 12-node (6-6-1) vSAN 7.0 stretched cluster for all production workloads.
The customer currently uses four different vSAN storage policies for running the workloads depending on the applications requirements:
* Policy 1 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Erasure Coding
* Policy 2 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Mirroring
* Policy 3 - Site Disaster Tolerance=None - Keep Data on Preferred, FTT=Mirroring
* Policy 4 - Site Disaster Tolerance=None - Keep Data on Non-Preferred, FTT=Mirroring During the setup of the vSAN stretched cluster, the following VM/Host Rules were created:
* Preferred Site - Preferred Site workloads should run on DC1 hosts.
* Secondary Site - Secondary Site workloads should run on DC2 hosts.
Which two activities should the administrator complete to ensure that there is no impact to production services during the maintenance window in the Preferred Site? (Choose two.)

  • A. Change the Site Disaster Tolerance setting in Policy 4 to be "None - Keep Data on Preferred".
  • B. Change the Site Disaster Tolerance setting in Policy 3 to be "Dual Site Mirroring".
  • C. Update vSphere DRS site affinity rules so that Preferred Site workloads must run on hosts in DC2.
  • D. Update vSphere DRS site affinity rules so that Preferred Site workloads should not run on hosts in DC1.
  • E. Change the FTT setting in Policy 3 to be "Erasure Coding".

Answer: A,C

 

NEW QUESTION 34
An administrator managing a vSAN cluster of six-nodes with policy FTT-2/RAID-6 decided to put one of the nodes in maintenance mode using the "Full-data migration" option.
What will happen after this action is taken?

  • A. The host will enter into maintenance mode if both components of a certain object are residing on that host, then one of the components will be moved to another available host.
  • B. The host will enter in maintenance mode and the data will remain accessible until the host exits maintenance mode.
  • C. The host will enter in maintenance mode and only data with no redundancy will remain accessible.
  • D. The system will prompt to add an additional host to the cluster in order to preserve the policy compliance.

Answer: B

 

NEW QUESTION 35
In a vSAN stretched cluster, which value must be set in the vSAN policy if there is no requirement for data mirroring across sites?

  • A. SFTT = 0
  • B. PFTT = 0
  • C. SFTT = 1
  • D. PFTT = 1

Answer: A

 

NEW QUESTION 36
......

100% Free 5V0-21.21 Daily Practice Exam With 52 Questions: https://examsboost.validbraindumps.com/5V0-21.21-exam-prep.html